Landscape concept handoff · selected direction

Internal wall & front verge

Final visual intent combining H + G internally and R externally. Each area includes an on-base before/final overlay, a generated alternate angle, the relevant originals, and construction hold points.

Issue01 · For site measure 2 August 2026 Brisbane, Queensland

01 · Internal wall garden

Slim raised channel, track-safe

G · correct ledgeH · raised trough formRestrained planting

A continuous charcoal trough sits only on the lawn-facing retaining ledge. It stops before the stair and sliding-gate track junction, leaving the fence-side service lane untouched.

Original track-side internal ledge before landscaping
Final slim charcoal raised planting channel on lawn-facing ledge with track and steps clear
FinalOriginal
Angle 01 · Direct base overlay

Track-side set-out

The operational check view. Sliding track, pavers, stair junction and fence-side dirt/service lane remain visible and clear.

Generated rotationAlternate wide view of same slim raised planter along internal retaining ledge
Angle 02 · Alternate viewpoint

Full-run consistency

Cross-checked against both source photos. Confirms the straight run, low profile and restrained flower rhythm along the boundary.

Relevant originals & concept sources

Source images used to constrain geometry and design lineage

Original internal wide angle
Original A · wideFull ledge run and rear boundary.
Original internal track angle
Original B · trackGate track, pavers and steps.
Gallery concept G embedded track-safe channel
Concept G · placementLawn-facing ledge; access lane clear.
Gallery concept H raised track-safe trough
Concept H · formRaised charcoal structure; density reduced in final.

Landscaper set-out brief

Use with site measurements and shop drawing

Internal wall garden · design and construction requirements
ItemRequirementSite confirmation
PositionSingle straight trough on lawn-facing ledge only. No element in fence-side service lane.Survey available ledge width and level changes.
Visual envelopeLow-profile channel; imagery targets about 300–350 mm wide and about 300 mm high.Indicative only—submit measured shop drawing before fabrication.
FinishMatte charcoal powder-coated metal; simple folded construction, concealed fixings, neat end caps.Confirm aluminium or suitably protected steel for exposure and soil contact.
Operational clearanceStop before stair/track junction; preserve every step, track component and maintenance route.Gate fully open/closed test; confirm manufacturer clearance and maintenance access.
Water & loadFree-draining planter assembly; no uncontrolled discharge onto track, stairs or retaining structure.Confirm ledge load capacity, waterproofing, outlets and legal drainage point.
Planting characterRestrained white, pale lavender and dusty-pink flowering rhythm; compact strappy foliage; sparse controlled trailers.Final cultivar, soil volume, spacing and quantities after sun/irrigation assessment.

Locally suitable planting candidates for the final horticultural schedule include dwarf forms of Dianella caerulea, Brachyscome multifida, Scaevola aemula and controlled Myoporum parvifolium; the landscaper should select cultivars that fit the measured soil volume and mature envelope. These plant types are described by Brisbane City Council as suitable for Brisbane conditions.

02 · Front verge

Low split hedge at true gate

R · true-gate split700 mm maximumOrganic mulch, flush grade

R’s short-left/long-right hedge layout is retained. The final lowers the hedge to Council’s 700 mm maximum and removes hard edging in favour of organic mulch flush with turf.

Original street-side white fence and grass verge
Final low split evergreen hedge on street side of white fence with true pedestrian gate clear
FinalOriginal
Angle 01 · Direct base overlay

Primary street-side set-out

The short section sits left of the true gate; the long run starts beyond it. The gate approach and broad grass pedestrian path remain open.

Generated rotationAlternate reverse view of same low split hedge with gate left of centre
Angle 02 · Alternate viewpoint

Gate-location check

The identified gate remains left of centre in the original geometry. Hedge height and grade treatment match the primary view.

Relevant originals & concept source

All exterior viewpoints used to lock the gate and fence geometry

Original front fence reverse view
Original C · reverseHouse-facing fence geometry.
Original front fence street view
Original D · streetPrimary verge and set-out view.
Original street view with true pedestrian gate outlined
Original E · true gateOrange box is reference only; not part of final.
Selected gallery concept R split hedge
Concept R · selected layoutGate split retained; edge and height made Council-ready.

Landscaper set-out brief

Public verge requirements are mandatory hold points

Front verge · design, access and Council requirements
ItemRequirementSite confirmation
LayoutTwo runs only: short section left of true pedestrian gate; long section right. Keep full gate width, latch and approach clear.Pin true gate edges from Original E; mark opening envelope on ground.
Mature envelopeLow-growing clipped hedge, maximum 700 mm high. Do not obstruct driveway sightlines.Record verge levels and sight triangles; choose naturally compact cultivar.
Ground planeOrganic mulch only, flush with adjoining grass. No steel edge, gravel, aggregate, planter box, hard landscape or irrigation.Submit turf-cut bed width and flush mulch sample.
Pedestrian accessContinuous unmade pedestrian path at least 1.2 m wide outside the mature hedge.Measure from mature foliage face, not mulch edge; retain kerb and vehicle access.
Services & accessUtilities, post, bins and public access must remain unobstructed; verge planting may be disturbed for service works.Obtain current Before You Dig Australia plans and pothole/locate as required.
Plant candidateCouncil-listed compact candidates include Syzygium australe ‘Tiny Trev’ or Austromyrtus dulcis, maintained below 700 mm.Landscaper to confirm cultivar availability, mature width, root habit and clipping response.

Authority basis: Brisbane City Council · Verge gardens, Verge Garden Guidelines, Recommended Planting List, and the Australian Government’s Before You Dig Australia overview, checked 2 August 2026. Do not substitute small-leaved privet (Ligustrum sinense), which Council identifies as Category 3 restricted matter.

03 · Internal validation record

Checks before handoff

The imagery and document were checked for concept fidelity, geometry, operational access, authority constraints, responsive containment and print legibility.

Handoff validation · issue 01
CheckResultEvidence / limitation
H/G concept lineagePassG fixes the lawn-facing ledge position; H supplies raised charcoal trough form; final planting density reduced.
Internal gate operationsVisual passTrack, pavers, steps and fence-side service lane remain clear in primary view. Physical clearance remains a site hold.
R gate splitPassBoth final exterior angles use the true left-of-centre pedestrian gate with short-left and long-right runs.
Verge compliance intentPass with holds700 mm maximum, 1.2 m path, organic mulch flush to grass, no hard landscape or irrigation. Site/zone/services confirmation required.
Image realismPass for concept handoffAlternate views were generated using all available photos for their area; lighting and major geometry were cross-checked. AI imagery is not survey evidence.
Document semanticsPassLandmarks, heading order, table captions, scoped headers, keyboard-focusable table frames and labelled comparison controls included.